Schaffner Siemens Drive

6SL3210-1PH24-2AL0

6SL3210-1PH24-2AL0: 6SL3210-1PH24-2AL0
With the second generation SINAMICS G120, Siemens presents a modular converter with higher power density and a space-saving frame size. The redesigned converter series is now available in three voltage variants for connection to 200 V, 400 V and 690 V.

PM240-2 Power Modules have a braking chopper (four-quadrant applications) and are suitable for a large number of applications in general machinery contruction
3 AC 200 V ... 240 V 5,5 kW ... 7,5 kW
3 AC 380 V ... 480 V 0,55 kW ... 250 kW
3 AC 500 V ... 690 V 11 kW ... 132 kW

PM250 Power Modules are suitable for the same applications as the PM240 Power Modules. Any braking energy is directly fed back into the line supply (four quadrant applications - a braking chopper is not required).
3 AC 380 V-480 V ±10% 7,5 kW bis 90 kW

Select Category

Passive harmonic filter

50 Hz

FN 3410 HV-45-53
690 VAC, rated load power 37 kW, 5% THID
FN 3410 HV-60-35
690 VAC, rated load power 45 kW, 5% THID

Output filter

dv/dt filter

FN 5060 HV-45-99
rated current 45 A @40°C/50 Hz, L=0.17 mH
FN 5060 HV-45-99
rated current 45 A @40°C/50 Hz, L=0.17 mH

Sine-wave filter

FN 5040 HV-45-86
rated current 45 A @40°C/50 Hz, minimum switching frequency 2 kHz, max motor cable length 1000 m
FN 5040 HV-45-86
rated current 45 A @40°C/50 Hz, minimum switching frequency 2 kHz, max. motor cable length 1000 m

EMC filter

Motor cable length ≤50 m class C1

FN 258 HV-42-33
max. 690 VAC up to 60 Hz, rated current 42 A @50°C, IP 20

Motor cable lenght ≤50 m class C2

FN 258 HV-42-33
max. 690 VAC up to 60 Hz, rated current 42 A @50°C, IP 20

Motor cable length >50 m class C1

FN 258 HV-42-33
max. 690 VAC up to 60 Hz, rated current 42 A @50°C, IP 20

Motor cable lenght >50 m class C2

FN 258 HV-42-33
max. 690 VAC up to 60 Hz, rated current 42 A @50°C, IP 20

For IT power networks class C2

FN 258 HVIT-42-33
max. 690 VAC up to 60 Hz, rated current 42 A @50°C, IP 20



Remarks EMC/EMI Filters:
All suggested Schaffner products are recommendations. The final suitability can be guaranteed only by a measurement in the application and is part of the responsibility of the customer. The information of the limit value class C1 or C2 covers only the conducted emission. The Drive Options, which are not produced by SIEMENS itself, nevertheless the manufacturer have a prozessual certification from SIEMENS, no liability is assumed by SIEMENS.

Remarks for 200 V Passive Harmonics and Output Filters:
The final filter suitability can only be guaranteed in terms of a measurement within the application and is part of the responsibility of the customer. All suggested Schaffner products are recommendations only.  Please use the document “Remarks for Schaffner Recommendation List” available in the Tools and Tips section of this page for further information.
Please be aware that dv/dt filters do only work on differential mode.
For those Drive Options that are not produced by SIEMENS itself, but manufacturer has a processual certification of SIEMENS, no liability is assumed by SIEMENS.

Remarks for 400 V Passive Harmonics and Output Filters:
The final filter suitability can only be guaranteed in terms of a measurement within the application and is part of the responsibility of the customer. All suggested Schaffner products are recommendations only.  Please use the document “Remarks for Schaffner Recommendation List” available in the Tools and Tips section of this page for further information.
Ecosine High Power line filters do require motor drives equipped with an 8% (minimum) DC-link choke or the application of a 4% (minimum) AC line choke at the input side of the drive!
Please be aware that dv/dt as well as sine wave filters do only work on differential mode. Dv/dt and sine wave filters ensure compliance with the requirements of IEC60034-17 (general purpose motors) for cable length named in the data sheets (screened/unscreened). Sine wave filters additionally do provide a sinusoidal phase-to-phase motor terminal voltage but have very limited effect on common mode.
For those Drive Options that are not produced by SIEMENS itself, but manufacturer has a processual certification of SIEMENS, no liability is assumed by SIEMENS.

Remarks for 690 V Passive Harmonics and Output Filters:
The final filter suitability can only be guaranteed in terms of a measurement within the application and is part of the responsibility of the customer. All suggested Schaffner products are recommendations only. Please use the document “Remarks for Schaffner Recommendation List” available in the Tools and Tips section of this page for further information.
Ecosine FN 3410 HV filters from 45 kW on do require motor drives equipped with DC-link choke or the application of a 4% (minimum) AC line choke at the input side of the drive!
Please be aware that dv/dt as well as sine wave filters do only work on differential mode. Dv/dt and sine wave filters ensure compliance with the requirements of IEC60034-25B (inverter duty motors) for cable length named in the data sheets (screened/unscreened). Sine wave filters additionally do provide a sinusoidal phase-to-phase motor terminal voltage but have very limited effect on common mode. For the use of general purpose motors on 690V with dv/dt or sine wave filters Schaffner does strongly recommend to contact Schaffner representative prior to any project in order to verify the suitability of the drive-output filter-motor-combination.
For those Drive Options that are not produced by SIEMENS itself, but manufacturer has a processual certification of SIEMENS, no liability is assumed by SIEMENS.